DSpace Repository

A Lightweight Robust Deep Learning Model Gained High Accuracy in Classifying a Wide Range of Diabetic Retinopathy Images

Show simple item record

dc.contributor.author Raiaan, Mohaimenul Azam Khan
dc.contributor.author Fatema, Kaniz
dc.contributor.author Khan, Inam Ullah
dc.contributor.author Azam, Sami
dc.contributor.author Rashid, Md. Rafi Ur
dc.contributor.author Mukta, Md. Saddam Hossain
dc.contributor.author Jonkman, Mirjam
dc.date.accessioned 2024-04-06T08:21:26Z
dc.date.available 2024-04-06T08:21:26Z
dc.date.issued 2023-05-01
dc.identifier.uri http://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/12021
dc.description.abstract Diabetic retinopathy (DR) is a common complication of diabetes mellitus, and retinal blood vessel damage can lead to vision loss and blindness if not recognized at an early stage. Manual DR detection using large fundus image data is time-consuming and error-prone. An effective automatic DR detection system can be significantly faster and potentially more accurate. This study aims to classify fundus images into five DR classes, using deep learning methods, with the highest possible accuracy and the lowest possible computational time. Three distinct DR datasets, APTOS, Messidor2, and IDRiD, are merged, resulting in 5,819 raw images. Before training the model, various image preprocessing techniques are applied to remove artifacts and noise from the images and improve their quality. Three augmentation techniques: geometric, photometric, and elastic deformation, are used to create a balanced dataset. A shallow convolutional neural network (CNN) is developed using three blocks of convolutional layers and maxpool layers with a categorical cross-entropy loss function, Adam optimizer, 0.0001 learning rate, and 64 batch size as a base model, and this is also employed to determine the best data augmentation method for further processing. A study to optimize the performance is then conducted by changing different components and hyperparameters of the base model, resulting in our proposed RetNet-10 model. Six cutting-edge models are employed for comparison. Our proposed RetNet-10 model performed the best, with a testing accuracy of 98.65%. MobileNetV2, VGG16, Xception, VGG19, InceptionV3 and ResNet50 achieved testing accuracies of 91.42%, 90.16%,89.57%, 88.21%, 87.68% and 87.23%, respectively. The model is also trained with several k values to assess its robustness. After image processing and data augmentation, using the combined dataset, and fine-tuning the base model, our proposed RetNet-10 model outperformed other automated methods for DR diagnosis. en_US
dc.language.iso en_US en_US
dc.publisher IEEE en_US
dc.subject Diabetic en_US
dc.subject Deep learning en_US
dc.subject Diagnosis en_US
dc.title A Lightweight Robust Deep Learning Model Gained High Accuracy in Classifying a Wide Range of Diabetic Retinopathy Images en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics