DSpace Repository

Thermoluminescence Characterization of Flooring Tiles From Malaysia for Potential Use in Retrospective Dosimetry

Show simple item record

dc.contributor.author Khandaker, Mayeen Uddin
dc.contributor.author Lam, Siok Ee
dc.contributor.author Daud, Amirul Najman Ariff Bin Md
dc.contributor.author Sani, Siti Fairus Abdul
dc.contributor.author Bradley, David Andrew
dc.contributor.author Alzimami, Khalid S.
dc.contributor.author Almohammed, Huda I.
dc.contributor.author Hamd, Zuhal Y.
dc.contributor.author Osman, Hamd F, Hamid
dc.date.accessioned 2024-10-03T08:14:13Z
dc.date.available 2024-10-03T08:14:13Z
dc.date.issued 2024-08-20
dc.identifier.uri http://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/13513
dc.description.abstract In the event of natural disasters or technical malfunctions at nuclear sites, the surrounding media, including individuals, may be subject to unforeseen radiation exposure. Thus, it is not possible to determine the precise level of radiation exposure that each person has received in this scenario. To handle such a problem, the use of retrospective dosimetry can offer an accurate evaluation of the radiation dose acquired as a result of such incidents. This information enables the development of suitable remedial actions. Normally, in the region that has been impacted, several artifacts can serve as natural dosimeters. The study involved the utilization of locally available seven different brands of flooring tiles in Malaysia for the possibility of being used in retrospective dosimetry through exposures to 60Co gamma-rays within a range of 10–200 Gy. To understand the luminescence features of this material, a convenient thermoluminescence (TL) technique has been employed. The dosimetric features of the samples were investigated, including their effective atomic numbers (Zeff), reproducibility, glow curve, dose response, sensitivity, linearity index, energy dependency and fading, which is representative of the usual TL method. Additionally, by analyzing the glow curves of the irradiated samples together with the peak shape method and the initial rise methods, several kinetic parameters, including the kinetic orders (b), activation energy (E) or trap depth, frequency factor (s) or escape probability, and trap lifetime (τ) were calculated. Different kinds of tiles exhibit distinct scenarios in terms of kinetic characteristics. T1 sample exhibits the highest degree of sensitivity and a highly linear dose response among the tile samples that were evaluated. Also, T1, T3, and T5 samples show minimal loss of TL intensity (∼38–39%) one year after irradiation, making them ideal for use as a retrospective dosimeter. en_US
dc.language.iso en_US en_US
dc.publisher Elsevier en_US
dc.subject Natural disasters en_US
dc.subject Natural calamities en_US
dc.title Thermoluminescence Characterization of Flooring Tiles From Malaysia for Potential Use in Retrospective Dosimetry en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account