DSpace Repository

The Influence of Thermal Treatment on the Structural Properties and Gamma Rays Shielding of Bentonite Clay Ceramic

Show simple item record

dc.contributor.author Alafer, Feras
dc.contributor.author Sallam, F.H.
dc.contributor.author Al Meshari, Meshari
dc.contributor.author Alzamil, Yasser
dc.contributor.author Abanomy, Ahmad
dc.contributor.author Alhujaili, Sultan
dc.contributor.author El-Taher, Atef
dc.date.accessioned 2024-10-03T08:32:28Z
dc.date.available 2024-10-03T08:32:28Z
dc.date.issued 2024-04-15
dc.identifier.uri http://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/13528
dc.description.abstract Bentonite clay has renowned in the gamma rays shielding field, as it is a natural, low-cost, obtainable, plentiful material and outstanding shielding ability. Bentonite clay was thermally activated at 900 °C, 1000 °C, and 1100 °C to acquire ceramic features with the desired porosity. Heat treatment of bentonite clay leads to mass loss due to dehydration and dihydroxylation process. The elemental composition of the different sintered bentonite ceramic samples was identified by X-ray fluorescence. The structure of bentonite ceramic samples was characterized by X-ray diffraction, particle size determination, and density measurements, moreover, a scanning electron microscope clarifies the surface morphology of the samples. Shielding measurements were investigated for different sintered bentonite ceramic samples against gamma rays using a sodium iodide detector and narrow beam transmission technique, in addition to two point sources Cs-137 and Co-60 which emits 662 keV, 1173 keV, and 1332 keV. It has been found that the ceramic samples sintered at 1100 °C have the best shielding parameters (linear attenuation coefficient, mass attenuation coefficient, half value layer, tenth value layer, and mean free path). Experimental values of the mass attenuation coefficient of the sintered sample at 1100 °C were compared with theoretical values estimated from both XCOM and Physics-X programs and found that there is a little difference between them that doesn't exceed 10%. At last, the radiation protection efficiency of all samples was calculated and concluded that the same sintered sample at 1100 °C is the optimum sample in all investigated properties. en_US
dc.language.iso en_US en_US
dc.publisher Elsevier en_US
dc.subject Thermal treatment en_US
dc.subject Clay ceramic en_US
dc.title The Influence of Thermal Treatment on the Structural Properties and Gamma Rays Shielding of Bentonite Clay Ceramic en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account