DSpace Repository

Comparative Study of Lateral Loads and Its Cost Effect on RC Moment Frame and Wall-frame Building According to BNBC 2020 in Different Zones of Bangladesh

Show simple item record

dc.contributor.author Hasan, Md. Abir
dc.contributor.author Debnath, Shraboni
dc.contributor.author Akther, Arifa
dc.date.accessioned 2022-02-01T06:18:03Z
dc.date.available 2022-02-01T06:18:03Z
dc.date.issued 2022-01-08
dc.identifier.issn 1818-5878
dc.identifier.issn 2408-8498
dc.identifier.uri http://dspace.daffodilvarsity.edu.bd:8080/handle/123456789/6941
dc.description.abstract With the advancement in material science, construction technology and structural analysis, a new building code was essential to keep pace with technological advantages. Recently introduced BNBC 2020 bridges the gap largely. A very basic change in lateral loading provision has occurred in the new code, which accounts for several newly defined parameters. For wind analysis, the new code introduces 3-second gust velocity as basic wind speed, wind pressure application in four cases that accounts for eccentricity. It considers topographic and internal pressure effect. A new seismic zoning is introduced in BNBC 2020 with revised PGA values and spectral acceleration. The code also introduces seismic design category and revised response reduction factor. All these changes will affect the design practice. To understand and compare lateral loading in different zones, a FEA of 20 storied RC building with and without core shear wall was analyzed using ETABS V18. The comparison shows that Rajshahi (Zone I) has lowest wind and seismic loading, Chattogram (Zone III) has highest seismic and wind loading while, Dhaka (Zone II) has moderate seismic and wind loading. Wall frame building has slightly larger seismic base shear while shear wall resists major portion of base shear and reduces top story displacement and story drift greatly. The cost of construction in zone III is significantly larger than in zone I and II. In all zones shear wall building imparts economic structural solution compared to bare frame against lateral loading for 20 storied buildings and the margin of economy increases with increasing lateral loading. en_US
dc.language.iso en_US en_US
dc.publisher ©Daffodil International University en_US
dc.subject Construction industry en_US
dc.subject Structural analysis en_US
dc.subject Lateral loads en_US
dc.title Comparative Study of Lateral Loads and Its Cost Effect on RC Moment Frame and Wall-frame Building According to BNBC 2020 in Different Zones of Bangladesh en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account