Abstract:
In today's scenario, buildings with floating columns are a common feature in modern multistory construction in the world. These floating columns are presented to the building so that it
can be used for both commercial and residential purposes, and they begin at the story level
where the building should be used as a residential building. The influence of floating columns
of an RC frame structure for G+8 story at zone 2 in Bangladesh was investigated in this study,
as well as the effect of floating column position at different locations in the considered plan. In
this study I make three cases by removing column for different side, after analysis I make a list
for taking the column that are not similar according all three cases, in this study, I found that,
whenever you remove a column then the building column size increased due to removed
column, so after analysis the building in first case I found that the maximum columns size
was 400X550mm in second case the maximum was 500X700mm and finally in the third case
it was 400x950mm so as we can see whenever we remove column then the column size
increased due to applied load. The repeatedly column that I have seen in all three cases is
column C19. Finally, analysis results in the building such as finding the maximum and
minimum size of the column, repeatedly column were discussed in this study.