dc.description.abstract |
The wind load effect on R.C.C. buildings has gotten a lot of attention for establishing specialized characteristics according to the BNBC 2020 which is gazetted in 2021. MS Excel can be used to assess wind load value for R.C.C Residential Buildings, and other structures. The values of wind loads for different storey displacement, for different palaces with different exposure was investigated. These results are compared with each-other. In this study, the maximum windward load and leeward load increases as the number of storeys increases, which increases due to wind loads. Again, the maximum windward load and leeward load increases as the exposure changes from A to B and C respectively. And percent maximum value for each division was found 32.61%. Maximum design wind load was found in Chattogram and minimum design wind load was found in Rajshahi division. |
en_US |