DSpace Repository

Towards individualised CT protocols: Stratifying radiation dose by DLP, weight and sex in North Indian healthcare facilities

Show simple item record

dc.contributor.author Mohi Ud, Maajid
dc.contributor.author Malik, Din
dc.contributor.author Alqahtani, Mansour M.
dc.contributor.author Hadadi, Ibrahim
dc.contributor.author Musa, Alamin
dc.contributor.author Alshihri, Abdulaziz A.
dc.contributor.author Loaz, Omer
dc.contributor.author Kajoak, Samih
dc.contributor.author Fagiry, Moram A.
dc.contributor.author Khandaker, Mayeen Uddin
dc.contributor.author Alshehri, Mohammed Ali
dc.contributor.author Mahmoud, Mustafa
dc.date.accessioned 2026-10-19T07:16:06Z
dc.date.available 2026-10-19T07:16:06Z
dc.date.issued 2026-04-30
dc.identifier.uri http://192.168.40.123:8080/handle/123456789/18179
dc.description Articles en_US
dc.description.abstract : Regardless of patient characteristics, current CT imaging techniques usually use standardised radiation settings, which could lead to needless radiation exposure, especially in smaller or lighter patients. Based on unique patient characteristics, this one-size-fits-all method falls short of optimizing the crucial balance between radiation dose and diagnostic image quality. The clinical problem addressed is the lack of evidence-based, patient-specific CT protocols that consider body habitus and sex-related anatomical differences to minimize radiation exposure while preserving diagnostic accuracy. This study aimed to quantify the relationships between radiation dose, as assessed by dose-length product (DLP), patient body weight, and sex across different CT scanner models, to develop individualised protocol recommendations for optimal radiation dose management. Methods A retrospective analysis was conducted on CT scan data of 900 adult patients who underwent head, chest, or abdomen-pelvis CT examinations across 10 different multi-detector CT scanners. The correlation between dose-length product (DLP) and body weight was assessed using Pearson's correlation coefficient. Mean dose-length product values were compared between males and females using an independent-samples t-test and across CT scanner models using a one-way ANOVA. Linear regression analysis was performed to establish predictive relationships between DLP and patient characteristics, with facility-specific correction factors developed for dose standardisation. Sex-specific regression models were created, and facility-specific correction factors were calculated to standardize dose comparisons across patient populations. Results We found a strong positive correlation between DLP and patient body weight (r = 0.61, p < 0.001), and this correlation varied across CT scanner models (r = 0.53-0.71). Mean dose-length product was markedly higher in male patients than in females (p = 0.002). A range of DLP differences was noted for the same examination type across multiple CT scanners (up to 46% difference in mean DLP). In some scanners, dose-length product values exceeded the recommended diagnostic reference levels. en_US
dc.language.iso en_US en_US
dc.publisher Scopus en_US
dc.subject Dose-length product en_US
dc.subject Body-weight en_US
dc.title Towards individualised CT protocols: Stratifying radiation dose by DLP, weight and sex in North Indian healthcare facilities en_US
dc.type Article en_US


Files in this item

This item appears in the following Collection(s)

Show simple item record

Search DSpace


Browse

My Account

Statistics