DSpace Repository

Natural flake graphite as an affordable dosimeter for clinical X ray application at dose ranges between 2-20 mGy

Show simple item record

dc.contributor.author Muslima, Umme
dc.contributor.author Khandaker, Mayeen Uddin
dc.contributor.author Nawi, S.N. Mat
dc.contributor.author Lam, S.E.
dc.contributor.author Sani, S.F. Abdul
dc.contributor.author Woo, H.J.
dc.contributor.author Wong, Jeannie Hsiu Ding
dc.contributor.author YEO, Chien Ing
dc.contributor.author Osman, Hamid
dc.date.accessioned 2026-11-01T07:36:19Z
dc.date.available 2026-11-01T07:36:19Z
dc.date.issued 2026-01
dc.identifier.uri http://192.168.40.123:8080/handle/123456789/18298
dc.description Articles en_US
dc.description.abstract The requirement for low-dose mammography is essentially important given the high radiosensitivity of breast tissue, coupled with the fact that screening programs necessitate multiple exposures throughout a patient's lifetime. Consequently, accurate dosimetry within the mammography dose range is crucial to guarantee safety and efficient dose measurement. Thermoluminescence (TL) along with microstructural analyses were performed on natural flake graphite (NFG) to evaluate its potential as a dosimeter for clinical X-ray applications, particularly within mammographic dose ranges (2–20 mGy). The study involved a thorough analysis of TL glow curves, dose-linearity, TL-sensitivity, signal loss, and repeatability. A 532 nm laser Raman spectroscopy and X-ray diffraction (XRD) were utilized to analyze the microstructure of the irradiated NFG. Promising characteristics of the NFG included a high response to dose (R2 of approximately 0.99 %), enhanced TL-sensitivity at lower level doses, and strong reproducibility (∼4 %). Following 28 days of irradiation, the fading rate was roughly 22 % in an ambient light room and 23 % in a dark room condition. Furthermore, the ratios of defect intensity (ID) to graphite intensity (IG), represented as ID/IG, closely reflected the oscillated pattern perceived in other carbonaceous materials. The structural parameters including crystallite size, dislocation-density, and lattice-strain, were assessed from the XRD pattern, confirming the dose-dependent structural changes and supportive to Raman and PL spectroscopy findings. The findings indicate that NFG might offer a promising candidate for developing a low-cost, hydrophobic, and human tissue-equivalent TL dosimeter, which might serve various applications in the healthcare field. en_US
dc.language.iso en_US en_US
dc.publisher Scopus en_US
dc.subject Thermoluminescence en_US
dc.subject Natural flake graphite en_US
dc.subject Dosimeter en_US
dc.subject Clinical X-ray Applications en_US
dc.subject Microstructural analyses en_US
dc.title Natural flake graphite as an affordable dosimeter for clinical X ray application at dose ranges between 2-20 mGy en_US
dc.type Article en_US