DSpace Repository

Significant research on meropenem cross-contamination management in a β-Lactam manufacturing unit: A high-performance liquid chromatography approach

Show simple item record

dc.contributor.author Ullah, Mohabbat
dc.contributor.author Obydulla, Obydulla
dc.contributor.author Sohel Rana, Md.
dc.date.accessioned 2026-11-03T03:49:30Z
dc.date.available 2026-11-03T03:49:30Z
dc.date.issued 2024-08-30
dc.identifier.uri http://192.168.40.123:8080/handle/123456789/18371
dc.description Article en_US
dc.description.abstract Rapid, simple, and sensitive high-performance liquid chromatography with diode-array detection (HPLC-DAD) techniques are described for quantitatively determining meropenem residue from the contact parts of injection filling machines. This involves swab sampling collected after cleaning. The method also addresses the management of meropenem cross-contamination in shared cephalosporin production facilities. Cross-contamination is the product mix-up by which a trace amount of antibiotics can be present in other products that cannot prevent infections but can contribute to initiating antibiotic-resistant pathogens into human microflora. Poor beta-lactam contaminant control can cause residual Meropenem in different dosage forms, resulting in meropenem residue in the human intestinal flora, blood during sepsis, or Environmental wastes. During manufacturing, there should be a validated scientific control with proper monitoring of meropenem contamination. Meropenem residue was determined on the contact parts of production machines using swab sampling collected from surfaces after cleaning. An isocratic chromatographic system used with a mobile phase consisting of acetonitrile: 20% tetrabutylammonium hydroxide adjusted to pH 6.5 ± 0.05 (30:70, v/v) on XTerra RP18 column at a flow rate 1.0 mL min-1 with an injection volume, 20 μL and UV (290 nm). HPLC-DAD method developed was found to be linear (R2 ≥ 0.999), sensitive, precise (RSD < 2.7%), accurate (recovery between 97% and 109%), and LOD and LOQ were obtained at 0.05 and 0.10 mg L-1, respectively. The area RSD (%) for six replicate injections of LOQ was 7.6. This study validated the Meropenem contaminant controlling procedure for drug manufacturers. en_US
dc.language.iso en_US en_US
dc.publisher Daffodil International University en_US
dc.subject Meropenem en_US
dc.subject High-Performance Liquid Chromatography en_US
dc.subject Antibiotic Resistance en_US
dc.subject Cross-Contamination en_US
dc.subject Drug Manufacturing Unit en_US
dc.subject Microflora en_US
dc.title Significant research on meropenem cross-contamination management in a β-Lactam manufacturing unit: A high-performance liquid chromatography approach en_US
dc.type Article en_US