Tempered glass as a thermoluminescent medium for retrospective dosimetryUmme Muslima, Mayeen Uddin Khandaker, S.E. Lam, S.N. Mat Nawi, S.F. Abdul Sani, Hamid Osman, Mohamed Y. Hanfi, M.I. Sayyed, D.A. Bradley

Show simple item record

dc.contributor.author Muslima, Umme
dc.contributor.author Uddin Khandaker, Mayeen
dc.contributor.author Lam, S.E.
dc.contributor.author Nawi, S.N. Mat
dc.contributor.author Abdul Sani, S.F.
dc.contributor.author Osman, Hamid
dc.date.accessioned 2026-11-04T11:15:55Z
dc.date.available 2026-11-04T11:15:55Z
dc.date.issued 2024-04-10
dc.identifier.uri http://192.168.40.123:8080/handle/123456789/18465
dc.description Article en_US
dc.description.abstract Globally, the use of nuclear facilities and the potential risks associated with the dispersal of ionizing radiation due to natural disasters or technical failures are on the rise. These risks can have severe consequences for the environment and all living organisms, particularly humans. There is currently no practical method available to accurately estimate the radiation doses received by the surrounding areas and individuals in such situations. To address this issue, retrospective dosimetry can be employed to estimate the actual radiation dose, followed by the implementation of remediation techniques. Considering this need, tempered glass, which is commonly used as a screen protector for smartphones by the general public, has been identified as a promising medium for retrospective dosimetry. The present study aimed to investigate the thermoluminescence (TL) properties of six different types of tempered glass subjected to 60Co gamma rays, specifically examining the TL dose response, linearity, repeatability, and fading. Among the various glass samples tested, HD anti-peep tempered glass demonstrates a highly linear dose-response and the greatest dose sensitivity within the examined dose range of 2–50 Gy. Additionally, the HD anti-peep tempered glass exhibits minimal loss of TL yield (∼23%) at 28 days post-irradiation, making it particularly suitable for use as a retrospective dosimeter. en_US
dc.language.iso en_US en_US
dc.publisher Daffodil International University en_US
dc.subject Smartphone Screen Protector Glass en_US
dc.subject Retrospective Dosimeter en_US
dc.subject Gamma Irradiation en_US
dc.subject Thermoluminescence Characteristics en_US
dc.title Tempered glass as a thermoluminescent medium for retrospective dosimetryUmme Muslima, Mayeen Uddin Khandaker, S.E. Lam, S.N. Mat Nawi, S.F. Abdul Sani, Hamid Osman, Mohamed Y. Hanfi, M.I. Sayyed, D.A. Bradley en_US